Installation, Operating and Maintenance
Instructions
MaxFire
TM
Multi-Fuel Room Heater
WARNING! Please read this entire manual before installation and use of the Bixby MaxFire
TM
Multi-Fuel
Room Heater. Failure to follow these instructions could result in property damage, bodily injury or even death.
Contact local building officials, fire officials or the authority having jurisdiction about restrictions, permits and
installation inspection requirements in your area.
Save these instructions for future reference.
PLEASE RECORD THE FOLLOWING INFORMATION:
MODEL _______________ DEALERSHIP _______________ INSTALLER _______________
DATE PURCHASED _______________ DEALER PHONE _______________ INSTALLER PHONE _______________
SERIAL NUMBER ____________________________
Bixby Energy Systems
877-500-2800
www.bixbyenergy.com
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - Multi-Fuel Room Heater

Installation, Operating and MaintenanceInstructionsMaxFireTM Multi-Fuel Room HeaterWARNING! Please read this entire manual before installation and u

Page 2

82020866 REV ALEVELING THE ROOM HEATERCAUTION: THE ROOM HEATER SHOULD BE LEVELED BEFORE ATTACHING THE VENT PIPE. The supplied bulls eye level can b

Page 3 - TABLE OF CONTENTS

92020866 REV AVENT SYSTEM APPROVALSBIXBY DIRECT VENT PIPE is listed by OMNI-Test Laboratories, Inc. as a vent for BIXBY pellet and corn Room Heaters o

Page 4 - SAFETY INFORMATION

102020866 REV AVENTING COMPONENTSINSPECTIONSThe use of pelletized fuel does not eliminate the need for inspection and cleaning. During the heating sea

Page 5 - Floor Protector

112020866 REV AVENT LOCATIONWhen exiting through walls, make sure NFPA rules are followed for distance from windows and openings. NOTE:The termination

Page 6 - SPECIFICATIONS

122020866 REV AVENT LOCATION (CONT.)Where passage through a wall, or partition of combustible construction is desired, the installation shall conform

Page 7

132020866 REV AVENTING CONFIGURATIONSThe allowable venting configuration is to be 25 equivalent horizontal feet (7.5 m) or less as determined through t

Page 8 - PLANNING THE INSTALLATION

142020866 REV AGENERAL VENT INSTALLATION INSTRUCTIONSFollow the Room Heater manufacturer’s instructions and safety manual for maximum efficiency and sa

Page 9 - Thermostat connection

152020866 REV AVERTICAL INTERIOR INSTALLATIONNOTE: Vertical exterior installation is not recommended due to excessive condensation.NOTE: Bixby recom

Page 10 - Leveling

162020866 REV AHORIZONTAL THROUGH-THE-WALL-INSTALLATION The flue exit is on back of the Room Heater, and if a horizontal through-the-wall installation

Page 11

172020866 REV AINSTALLATION IN A CATHEDRAL CEILING1. Mark a line on the side of the Cathedral Ceiling Support Box to correspond to the line

Page 13 - See below for more details

182020866 REV AINSTALLATION IN A CATHEDRAL CEILING (CONT.)8. Place the Vertical Support Clamp (5000576), around the top of the hole in the bottom of

Page 14 - 240mm to 250mm

192020866 REV ACONNECTING TO EXISTING CLASS A CHIMNEY EITHER 6” OR 8”Due to cleaning, inspection and condensation issues, Bixby no longer recomends co

Page 15

202020866 REV ALOG PLACEMENT INSTRUCTIONSThe use of the logs provided with the Room Heater is optional.1. Locate the log box and remov

Page 16 - 2020866 REV A

212020866 REV AFUELIt is strongly recommended that only Dry Shelled Corn (whole kernels), Wood Pellets (recommended maximum size approx

Page 17

222020866 REV ASTART UPNOTE: It is recommended that all gold or silver plated surfaces of the Bixby Room Heater be cleaned with a mild glass cleaner

Page 18

232020866 REV AThe 8 heat level indicator lights on the Bixby Room Heater are also designed to act as potential problem indicators. Whenever one of t

Page 19

242020866 REV AMAINTENANCE AND CLEANING PROCEDURESThe Bixby Room Heater has been designed to reduce the frequency of cleaning. However,

Page 20

252020866 REV AAsh DrawerFigure 28HEAT EXCHANGER TUBESFly ash and other deposits will accumulate on the Heat Exchanger Tubes over time and will a

Page 21

262020866 REV ACLEANING THE EXHAUST MANIFOLDThe Exhaust Manifold should be cleared on a yearly basis to ensure proper air flow in the Room Heat

Page 22 - LOG PLACEMENT INSTRUCTIONS

272020866 REV AFUEL HOPPERThe Fuel Hopper should be cleaned out on a regular basis (monthly) to remove fines and ensure proper fuel delivery.

Page 23 - OPERATING INSTRUCTIONS

12020866 REV ATABLE OF CONTENTSSafety Information 2Minimum Clearances to Combustible MaterialsSpecifications 4Planning the Installation 6Performing

Page 24

282020866 REV ACLEANING THE LOWER PADDLEThe Lower Paddle needs to be cleaned once a month in order to operate efficiently. The ash dumping pro

Page 25 - 1 2 3 4 5 6 7 8

292020866 REV ATROUBLESHOOTING PROCEDURESWhen experiencing a malfunction, please read through the following list of possible problems to determine whi

Page 26 - Fuel deflector

302020866 REV APROBLEM POSSIBLE CAUSE/REMEDYFire fails to start Be sure enough fuel is in the burn pot. Fuel should cover the bottom to a level of ap

Page 27

312020866 REV AWIRING DIAGRAMFigure 37MFG APPR.QA APPR.ENG APPR.DRAWN BYDATENAMESHEET 1 OF 1IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BI

Page 28 - Fan Cover

322020866 REV ASERVICE PARTS LISTItem Number Description Part Location4000080 Igniter4000121 Air pump4000113 Burner drive motor assembly4000006 Feeder

Page 29 - Figure 34

332020866 REV AItem Number Description Part Location4000022 Heat exchanger cover plate - RightHeat exchanger cover plate - Left4000048 Air Filter40000

Page 30 - Burn Pot

342020866 REV AItem Number Description Part Location4000353 Burner top plate4000361 Feed wheel sensor4000379 Fuel deflector4000329 Thermocouple4000337

Page 31 - TROUBLESHOOTING PROCEDURES

352020866 REV ADescription Color / Size Part #Vertical Termination Cap Black 5001368 Wall Thimble Aluminized Steel 5000526 Storm Collar Stainless Stee

Page 32 - TROUBLESHOOTING CONT

362020866 REV ADescription Color / Size Part #6” Straight Pipe Black 5000055Blushtone* 5000063Hunter Green* 500008912” Straight Pipe Black 5000170Burg

Page 33 - WIRING DIAGRAM

372020866 REV ADescription Color / Size Part #Decorative Collar Black 5000740 Blushtone* 5000758Hunter Green* 5000774Sheet Metal Screw Black 5000857Bl

Page 34 - SERVICE PARTS LIST

22020866 REV ASAFETY INFORMATION1. Install and use only in accordance with these installation and operating instructions, page 9. Contact local buil

Page 35

382020866 REV ADate Service Performed NotesMAINTENANCE LOG

Page 36 - OPTIONAL ACCESSORIES

32020866 REV AMINIMUM CLEARANCES TO COMBUSTIBLE MATERIALSUse a non-combustible floor protector under the unit, extending 3” (76mm) past the side of un

Page 37 - VENTING PARTS LIST

42020866 REV ASPECIFICATIONSFuel: Multi-fuel System: Dry shelled corn, Wood Pellets (recommended maximum size approximately ¼ in. diameter x 1¼

Page 38 - VENTING PARTS LIST (CONT.)

52020866 REV AIMPORTANT: Proper material handling equipment must be available to safely transport and position the Bixby Room Heater. 1. Remove the

Page 39

62020866 REV APLANNING THE INSTALLATIONThe Bixby Max-FireTM Room Heater is intended for use in buildings, manufactured homes or for mobile home instal

Page 40 - MAINTENANCE LOG

72020866 REV AFEEDRATE3535- 0 +THERMOSTAT CONNECTION2021781 REV AEXHAUSTFAN- 0 +3535FUELCORN WOOD OPTIONAL THERMOSTAT OPE